product_id: 14510521
title: "Connecticut Electric EmerGen Transfer Switch"
brand: "connecticut electric"
price: "263.40 OMR"
currency: OMR
in_stock: true
reviews_count: 13
category: "Connecticut Electric"
url: https://www.desertcart.com.om/products/14510521-connecticut-electric-emergen-transfer-switch
store_origin: OM
region: Oman
---

# 30 Amp max current 10-circuit versatile control NEMA 3R rainproof rating Connecticut Electric EmerGen Transfer Switch

**Brand:** connecticut electric
**Price:** 263.40 OMR
**Availability:** ✅ In Stock

## Summary

> ⚡ Power up your peace of mind — never be left in the dark again!

## Quick Answers

- **What is this?** Connecticut Electric EmerGen Transfer Switch by connecticut electric
- **How much does it cost?** 263.40 OMR with free shipping
- **Is it available?** Yes, in stock and ready to ship
- **Where can I buy it?** [www.desertcart.com.om](https://www.desertcart.com.om/products/14510521-connecticut-electric-emergen-transfer-switch)

## Best For

- connecticut electric enthusiasts

## Why This Product

- Trusted connecticut electric brand quality
- Free international shipping included
- Worldwide delivery with tracking
- 15-day hassle-free returns

## Key Features

- • **Plug & Play Ready:** Includes a 10-foot generator cord and inlet box for straightforward, DIY-friendly installation.
- • **Built for All Weather:** NEMA 3R rainproof rating means reliable indoor/outdoor installation without worry.
- • **Safe & Smart Switching:** Double-throw rocker switches eliminate back-feed risks, keeping your home and utility lines protected.
- • **Seamless Power Control:** Manage up to 10 circuits with a robust 30 Amp capacity for your whole-home backup needs.
- • **Universal Compatibility:** Works flawlessly with all major residential load centers—Challenger, Siemens, Square D & more.

## Overview

The Connecticut Electric EmerGen Transfer Switch Kit is a 30 Amp, 10-circuit transfer switch designed for portable generators up to 7500 watts. Featuring a rainproof NEMA 3R rating, it supports both indoor and outdoor installation and is compatible with all major residential load centers. Its double-throw rocker switches ensure safe, back-feed-free power transfer, making it a reliable, easy-to-install solution for emergency home power management.

## Description

desertcart.com: Connecticut Electric EmerGen Transfer Switch Kit - 30 Amp, 10-Circuit, 10-Foot Cord, 7500 Watts, for Generator : Patio, Lawn & Garden

Review: Excellent generator switch.... - Update for Sept 2020: Transfer switch has been working well when I have outages. Needed to use it the other day for a 30 hour outage. One of the rocker switches was not working. I contacted Connecticut Electric and they are sending me a new switch under warranty. Can't complain about that. It would be better if had not broken. I also bought an extra one. You can get replacements here on desertcart (https://www.desertcart.com/gp/product/B01LYCWB8P/ref=ox_sc_act_title_1?smid=ATVPDKIKX0DER&psc=1). Did some reading that indicates these switches are prone to failure. I hope that's not the case. If you need to replace 10 of them that's almost the cost of a new transfer switch. I bought 2 new ones so I have have a spare. Leaving this at 5 stars. Losing 1 switch out of 10 after 5 years does not seem like a big issue. Original review below: Overall a very nice transfer switch that works as expected. As others have noted, it seems to be more solidly built than most others and less expensive. Installation is fairly straightforward and not difficult if you have basic wiring understanding or experience. It’s a matter of being comfortable getting into your electrical panel or not. If not, this would be very easy for an electrician. The instructions are good and made the electrical work go quickly. You need to have some basic home maintenance skills to install the box and generator inlet (finding a place to put the switch, mounting it, mounting the inlet box and wiring it up, etc.). This switch feels substantial and is well thought out. A couple of things could be done better - see my comments below. But I would use this one again relative to the others I looked at (Reliance, Generac, etc.). Mounting the transfer switch and running the wires into my panel were by far the hardest part of this. My electrical panel is flush mounted in a wall so I had to cut drywall and hole-cut some studs to get the wires run. Not too difficult, but took some effort and I had to do some drywall patching when I was done. Several people have complained about the short generator power inlet leads. These aren’t meant to connect to the generator power inlet. The instructions make it clear that they expect you to run those to a junction box and then run that to the inlet. There’s no way for the manufacturer to know where your inlet will be relative to the panel – it could be 6" away or 60'. They'd couldn't possibly include the materials needed to make the inlet work for everybody (Romex, conduit, junction boxes, or whatever a specific installation may need). One trip to the hardware store does not seem unreasonable to get this thing wired up. One complaint I have is that the generator inlet box is meant for external use only. The documentation makes it clear that the box is not meant for indoor use. I’m not sure why this would be, or if this means it should not be used in a garage. Given that mine is in the garage I ordered a new inlet. It worked out better because I didn’t want to deal with a downward facing connection when the power is out. But not clear at all why the provided inlet is meant for external use only. One big improvement (for my use) would be an option to move the generator inlet into the switch box itself. I installed my switch in the garage near the power panel. It would have been far more convenient for me to have the inlet on the front or side of the switch. (For example, look at the Reliance Controls 310 CRK. It has an external inlet box but also has a cutout for the inlet to be mounted in the transfer switch.) This is a minor issue and it cost me $35 to get another inlet and put it in a box next to the transfer switch. Just something to consider if they ever update this product. This box connected well and works as expected. It could not be much easier to install and works with my 7500W generator perfectly. I printed out instructions and attached them to my generator handle so anybody in the house reliably and safely get the house on generator power when needed. This switch is well priced and easy to install. It's a much better and safer option than using a suicide cord or powering your entire panel and dealing with power management issues. EDIT: Did some reading. I suspect one reason they don't have an option for the inlet on the box is that they don't want people putting the inlet indoors or in the garage due to the potential for carbon monoxide poisoning if a door or window has to be left open to run the inlet cable. This is a real concern and has me reconsidering my setup where I put my generator in the garage with the door open. I'm now adding two CO detectors in the garage so I'll know if CO ever builds up in there.
Review: Works great with my shed. - I bought this to use with our new shed, which I'm currently powering from a generator. I'm very impressed with the quality - it is well made and comes with a lot of parts. It is bigger than I need now, but I plan to build a treehouse of sorts over the shed someday and I will use the other half of the circuits for the treehouse. FYI, I used 6 of the 12 circuits for my shed: two outdoor outlets, two indoor outlets, lights, and a (future) air conditioning unit. The instructions are pretty clear if you know a little about wiring. I did have to swap the wire outputs from the right side of the box to the left side, but that really wasn't a problem and the instructions are clear how to do that. So far it is watertight and performing flawlessly. It is really nice that it comes with the generator cable and the waterproof inlet plug. I installed this box and the inlet plug on the outside of the shed and routed the wires to the inside of the shed through PVC electrical pipe. Inside I connected it into a circuit panel I installed there, following the instructions in the manual. I did have to buy a few extra parts: the included generator cable has a 30Amp plug on it and I had to buy a 20Amp-to-30Amp adapter to use it with my generator (this was cheaper than buying a 20Amp cable). I also had to buy a short length of PVC electrical pipe to route the wires into the shed, a 90-degree plastic turn, and another straight-line plastic connector to feed the wires into the indoor circuit panel. As I said above, the quality of the box is exceptional. It should last for decades. It's also very heavy to hold up while installing! My only complaint is that both plastic connectors provided were cracked on the inside cylinder. I replaced the smaller one and used the larger one since it wasn't cracked too too bad. The picture is misleading a little - the inlet box is resting in the door of the box in the picture, but it doesn't actually go there. It is installed in a separate location near the box. I installed it directly below the box so I could use a straight piece of PVC pipe to connect them together. I'm very happy with the quality of this device. As a bonus, the instructions were very clear. I will probably buy another one in the future to use with my house since the previous owner did not use a transfer switch when wiring the house generator circuit.

## Features

- FOR PORTABLE GENERATOR: This transfer switch kit is designed to be used with emergency generators that have up to a 30-amp output, NEMA L14-30 receptacle. With easy-to-follow instructions, this unit is straightforward to install and a cheaper and safer alternative to running your portable generator without it.
- VOLTAGE: This transfer switch kit has four 2-pole 240-volt circuits, making it perfect for well or water sump pump applications. If you do not have use for 240-volt circuits, the tie bars can be removed allowing four additional single-pole circuits.
- INDOOR OR OUTDOOR: The transfer switch and accompanying power inlet can be used indoors or outdoors and have a NEMA 3R rainproof rating providing increased flexibility and peace of mind.
- POWER SURGE PROTECTION: The double-throw rocker switches completely eliminate the possibility of power back-feeding to the utility line or your generator when power is restored. All Connecticut Electric products are ETL listed, ensuring their compliance with UL Standards.
- COMPATIBLE WITH ALL LOAD CENTERS: This transfer switch is compatible with all residential load centers, including: Challenger, Cutler Hammer, GE, Homeline, Siemens, Square D, and Westinghouse.

## Technical Specifications

| Specification | Value |
|---------------|-------|
| ASIN | B005FQJD7K |
| Actuator Type | Hinge Lever |
| Best Sellers Rank | #108,547 in Patio, Lawn & Garden ( See Top 100 in Patio, Lawn & Garden ) #84 in Outdoor Generator Transfer Switches |
| Brand | Connecticut Electric |
| Brand Name | Connecticut Electric |
| Circuit Type | 10-way |
| Color | Grey |
| Compatible Devices | Challenger, Cutler Hammer, GE, Homeline, Siemens, Square D, Westinghouse |
| Connectivity Protocol | X-10 |
| Connector Type | Plug In |
| Contact Material | Alloy Steel |
| Contact Type | Normally Closed |
| Control Method | Touch |
| Control Type | manual |
| Current Rating | 30 A |
| Customer Reviews | 4.6 out of 5 stars 1,347 Reviews |
| Global Trade Identification Number | 00094925033588 |
| Included Components | Inlet Box |
| International Protection Rating | IP54 |
| Item Dimensions | 11.5 x 20.5 x 14.5 inches |
| Item Type Name | 10 CIRCUIT TRANSFER SWITCH KIT |
| Manufacturer | Connecticut Electric |
| Material Type | Alloy Steel (contacts), Plastic (body) |
| Model | EGS107501G2KIT |
| Mounting Type | Panel Mount |
| Number of Items | 1 |
| Number of Positions | 1 |
| Operating Voltage | 240 volts |
| Operation Mode | ON-OFF |
| Part Number | EGS107501G2KIT |
| Switch Type | Rocker |
| Terminal | Screw |
| UPC | 094925033588 |
| Unit Count | 1 Count |
| Upper Temperature Rating | 180 °F |
| Warranty Description | 5-Year |
| Wattage | 7500 watts |

## Product Details

- **Brand:** Connecticut Electric
- **Connector Type:** Plug In
- **Contact Type:** Normally Closed
- **Current Rating:** 30 A
- **Item dimensions L x W x H:** 11.5 x 20.5 x 14.5 inches
- **Material:** Alloy Steel (contacts), Plastic (body)
- **Operating Voltage:** 240 volts
- **Operation Mode:** ON-OFF
- **Switch Type:** Rocker
- **Terminal:** Screw

## Images

![Connecticut Electric EmerGen Transfer Switch - Image 1](https://m.media-amazon.com/images/I/61BzZmaiCuL.jpg)
![Connecticut Electric EmerGen Transfer Switch - Image 2](https://m.media-amazon.com/images/I/91GXOqCPxLL.jpg)
![Connecticut Electric EmerGen Transfer Switch - Image 3](https://m.media-amazon.com/images/I/81x4x4ItW2L.jpg)
![Connecticut Electric EmerGen Transfer Switch - Image 4](https://m.media-amazon.com/images/I/71l9SGIPTtL.jpg)
![Connecticut Electric EmerGen Transfer Switch - Image 5](https://m.media-amazon.com/images/I/61s1o9dgF1L.jpg)

## Questions & Answers

**Q: Where can i get parts for this egs? i need one of the panel switches and a vu meter?**
A: Most parts can be bought here on Amazon and other larger online retailers. The rocker switch is item EGS20RSA and the meter is EGS3750WMNS.

**Q: I presume it is OK to mix and match 120v and 240v circuits in the switch? My well pump is 240v while all other are 120v while considering balance.**
A: Yes. I have a 55 kw generator. I use 2 220v circuits one is water heater other is dryer. Turn of water heater when using drier. Refrig and microwave and coffee maker are opponent legs. Split computer and TV with the light on the other circuits. No issues with balance

**Q: Manual de conexiones**
A: Si

**Q: Will this power an a/c system if generator is big enough?**
A: Yes, but you have to be selective on what your powering! You can't run everything, have to stay with in it's limits!

## Customer Reviews

### ⭐⭐⭐⭐⭐ Excellent generator switch....
*by D***N on August 14, 2017*

Update for Sept 2020: Transfer switch has been working well when I have outages. Needed to use it the other day for a 30 hour outage. One of the rocker switches was not working. I contacted Connecticut Electric and they are sending me a new switch under warranty. Can't complain about that. It would be better if had not broken. I also bought an extra one. You can get replacements here on Amazon (https://www.amazon.com/gp/product/B01LYCWB8P/ref=ox_sc_act_title_1?smid=ATVPDKIKX0DER&psc=1). Did some reading that indicates these switches are prone to failure. I hope that's not the case. If you need to replace 10 of them that's almost the cost of a new transfer switch. I bought 2 new ones so I have have a spare. Leaving this at 5 stars. Losing 1 switch out of 10 after 5 years does not seem like a big issue. Original review below: Overall a very nice transfer switch that works as expected. As others have noted, it seems to be more solidly built than most others and less expensive. Installation is fairly straightforward and not difficult if you have basic wiring understanding or experience. It’s a matter of being comfortable getting into your electrical panel or not. If not, this would be very easy for an electrician. The instructions are good and made the electrical work go quickly. You need to have some basic home maintenance skills to install the box and generator inlet (finding a place to put the switch, mounting it, mounting the inlet box and wiring it up, etc.). This switch feels substantial and is well thought out. A couple of things could be done better - see my comments below. But I would use this one again relative to the others I looked at (Reliance, Generac, etc.). Mounting the transfer switch and running the wires into my panel were by far the hardest part of this. My electrical panel is flush mounted in a wall so I had to cut drywall and hole-cut some studs to get the wires run. Not too difficult, but took some effort and I had to do some drywall patching when I was done. Several people have complained about the short generator power inlet leads. These aren’t meant to connect to the generator power inlet. The instructions make it clear that they expect you to run those to a junction box and then run that to the inlet. There’s no way for the manufacturer to know where your inlet will be relative to the panel – it could be 6" away or 60'. They'd couldn't possibly include the materials needed to make the inlet work for everybody (Romex, conduit, junction boxes, or whatever a specific installation may need). One trip to the hardware store does not seem unreasonable to get this thing wired up. One complaint I have is that the generator inlet box is meant for external use only. The documentation makes it clear that the box is not meant for indoor use. I’m not sure why this would be, or if this means it should not be used in a garage. Given that mine is in the garage I ordered a new inlet. It worked out better because I didn’t want to deal with a downward facing connection when the power is out. But not clear at all why the provided inlet is meant for external use only. One big improvement (for my use) would be an option to move the generator inlet into the switch box itself. I installed my switch in the garage near the power panel. It would have been far more convenient for me to have the inlet on the front or side of the switch. (For example, look at the Reliance Controls 310 CRK. It has an external inlet box but also has a cutout for the inlet to be mounted in the transfer switch.) This is a minor issue and it cost me $35 to get another inlet and put it in a box next to the transfer switch. Just something to consider if they ever update this product. This box connected well and works as expected. It could not be much easier to install and works with my 7500W generator perfectly. I printed out instructions and attached them to my generator handle so anybody in the house reliably and safely get the house on generator power when needed. This switch is well priced and easy to install. It's a much better and safer option than using a suicide cord or powering your entire panel and dealing with power management issues. EDIT: Did some reading. I suspect one reason they don't have an option for the inlet on the box is that they don't want people putting the inlet indoors or in the garage due to the potential for carbon monoxide poisoning if a door or window has to be left open to run the inlet cable. This is a real concern and has me reconsidering my setup where I put my generator in the garage with the door open. I'm now adding two CO detectors in the garage so I'll know if CO ever builds up in there.

### ⭐⭐⭐⭐⭐ Works great with my shed.
*by M***T on April 1, 2016*

I bought this to use with our new shed, which I'm currently powering from a generator. I'm very impressed with the quality - it is well made and comes with a lot of parts. It is bigger than I need now, but I plan to build a treehouse of sorts over the shed someday and I will use the other half of the circuits for the treehouse. FYI, I used 6 of the 12 circuits for my shed: two outdoor outlets, two indoor outlets, lights, and a (future) air conditioning unit. The instructions are pretty clear if you know a little about wiring. I did have to swap the wire outputs from the right side of the box to the left side, but that really wasn't a problem and the instructions are clear how to do that. So far it is watertight and performing flawlessly. It is really nice that it comes with the generator cable and the waterproof inlet plug. I installed this box and the inlet plug on the outside of the shed and routed the wires to the inside of the shed through PVC electrical pipe. Inside I connected it into a circuit panel I installed there, following the instructions in the manual. I did have to buy a few extra parts: the included generator cable has a 30Amp plug on it and I had to buy a 20Amp-to-30Amp adapter to use it with my generator (this was cheaper than buying a 20Amp cable). I also had to buy a short length of PVC electrical pipe to route the wires into the shed, a 90-degree plastic turn, and another straight-line plastic connector to feed the wires into the indoor circuit panel. As I said above, the quality of the box is exceptional. It should last for decades. It's also very heavy to hold up while installing! My only complaint is that both plastic connectors provided were cracked on the inside cylinder. I replaced the smaller one and used the larger one since it wasn't cracked too too bad. The picture is misleading a little - the inlet box is resting in the door of the box in the picture, but it doesn't actually go there. It is installed in a separate location near the box. I installed it directly below the box so I could use a straight piece of PVC pipe to connect them together. I'm very happy with the quality of this device. As a bonus, the instructions were very clear. I will probably buy another one in the future to use with my house since the previous owner did not use a transfer switch when wiring the house generator circuit.

### ⭐⭐⭐⭐⭐ EmerGen EGS107501G2KIT Switch 10-7501G2,..
*by K***E on August 24, 2016*

I got it for like $283.95 free shipping....but needed a way to hook up easily my whole house with selections of what circuits to use.... After having my installation certified by a local electrician, and a generator test to the box, only a week and a half our power went out for 11 hours and we got to use the box and we were excited how easy it was to just flip switches to select what we wanted to use in the house. We actually ran everything we needed..all our plugins and refrigerators....a ceiling fan..the 50 " tv...our internet, charge up our kindles and laptop. This product is built tough as nails. Set up was easy...andusing it was even easier..we had to clap and laugh at how easy it was to operate. and when the power came back on....we simply shut down the generator outside and unplugged it from the house.. went into the basement and flipped the switches back from Gen to Line..and didn't miss a peat..and didnt have to reset any of our clocks. I did not realize our 5700 watt generator ran everything in our small home except the two refrigerators on the same side of the breaker.. so i will rewire them to the left side of the EmerGen box so the load on the generator will be even. You have to balance the load of the generator left and right side of the EmerGen box within 1000 watts of each other so you don't tax the one side of the generator because that can ruin your generator useless. We can run the furnace in the winter...but have to watch again the load on either side of the EmerGen box within 1000 watts. so you may have to shut off some switches on the same side so there is not alot of load on the furnace side..etc. I would not suggest you run the A/C units.. because unless you have a very big wattage generator. . . you may not be able to balance the loads on the left and right wattage meters and possibly damage the generator. So you will have to either fix this by wiring some heavier usage units on one side only...or shut off other switches on that same side so the bigger users can operate and you can balance the load on the wattage meters on the EmerGen box. I can only wish I was knowledgeable earlier years ago and wasnt so scared to do this install. Earlier we just ran the generator and ran extention cords all over the house..and ran the two refrigerators each two hours then unplugged it and plugged it into the other refrigerator..what a pain. We had power to operate our microwave. .. our gas stove with electric start..make oatmeal..coffee...toast...then go watch the morning news..while surfing the internet..and have the living room ceiling fan on(because i did not wire the A/c into the box.). The next thing we need to do is build a sound proof box to put around the loud generator..we had to wait untill 5:30 in the morning so we wouldn't wake up the neighbors.. by that time.. our refrigerators were in serious need to be ran.. and after setting up the generator..it was quick and easy... This EmerGen Box is perfect if you have a portable generator already.. and don't want the expense of a natural gas unit set up next to your house permanently. Buy one today. We purchased our on www.amazon.com free shipping ..new in box...i installed it myself.....electrician came to certify it..and i sent a copy of the certification to my home insurance provider... made my life most livable after knowing it works like a charm and easy to understand. comes with instructions and a generator start up proceedure sheet laminated with a chain to hang on or near the box. WONDERFUL PRODUCT!

## Frequently Bought Together

- Connecticut Electric EmerGen Transfer Switch Kit - 30 Amp, 10-Circuit, 10-Foot Cord, 7500 Watts, for Generator
- GEARit 30-Amp Generator Extension Cord (25 Feet) 4-Prong 120/250-Volt 7500W, NEMA L14-30P/L L14-30R, 10 Gauge SJTW Locking Power Cord for Manual Transfer Switch, Portable Generators, Power Outage 25ft
- Westinghouse 12500 Watt Dual Fuel Home Backup Portable Generator, Remote Electric Start, Transfer Switch Ready, Gas and Propane Powered

---

## Why Shop on Desertcart?

- 🛒 **Trusted by 1.3+ Million Shoppers** — Serving international shoppers since 2016
- 🌍 **Shop Globally** — Access 737+ million products across 21 categories
- 💰 **No Hidden Fees** — All customs, duties, and taxes included in the price
- 🔄 **15-Day Free Returns** — Hassle-free returns (30 days for PRO members)
- 🔒 **Secure Payments** — Trusted payment options with buyer protection
- ⭐ **TrustPilot Rated 4.5/5** — Based on 8,000+ happy customer reviews

**Shop now:** [https://www.desertcart.com.om/products/14510521-connecticut-electric-emergen-transfer-switch](https://www.desertcart.com.om/products/14510521-connecticut-electric-emergen-transfer-switch)

---

*Product available on Desertcart Oman*
*Store origin: OM*
*Last updated: 2026-09-02*